TTDDCC--110000//220000UUsseerr’’ss GGuuiiddee
Station Settings allows you to set parameters specific to each station. Use the Up or Down Arrows to navigate through the menus.Use the Left and Righ
The TDC-100/200 features 10 fully-independent resident programs. With two types of programs to select from,you can further custom fit your irrigation
8. Press the Down Arrow to advance the cursor to the Sta Dly: field. Use the Left and Right Arrow Keysto navigate between the Hour and Minute fields.
Grow In Irrigation Program Setting:Grow In Irrigation Program example: Create program 3 with stations 21–30 for 5 minutes each with no percentadjustme
The Manual Watering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to troubleshoot each
Syringe - Choose Syringe to activate all the stations in a selected irrigation program for a specified runtime. Note: The Maximum number of simultaneo
The percent adjust function allows you to fine tune irrigation programs. With weather conditions changingconstantly, Percent Adjust allows you to tune
The Pause command is used to suspend active program or manual irrigation. The Pause function allows theuser to specify the pause duration.Pause / Resu
Pause Function TDC-100/200 ActionPause Program XX Allow the start of other programs, multi-manuals and syringe. If the start time of thepaused progra
The diagnostics function allows the user to monitor Radio Link status, check the firmware version, troubleshootstations using the Sequence Stations op
22
Power Supply:1.5A On/Off Switch/Circuit Breaker – Main Power Input3.15A Fuse (Slow-Blow) – Field OutputMother Board: 3.15A FuseLine Voltage: 100, 220
Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4General Editing - - - - - - - - - - - - - - - - - - -
The Toro TDC-100/200 combines modular flexibility, ease of use and increased programmability in a single controller. Modularity means flexibility. Th
1 Left and Right Arrows allow you to select the next entry field within the same menu line. Anychanges will be saved after you exit that entry field.2
16 Power LED17 Daughter Board Fuse (8), 3.15A Fast-BlowDaughter Board Components661 Station Watering LED2 Pump ON LED3 Pump Pressure LED4 Rain Sensor
Upon power-up, the controller will display:The TDC-100/200 will initiate a diagnostic test automatically during power-up. This function will take appr
System Settings allows you to set controller parameters such as Time, Date and Language. Use the Up or Down Arrows to navigate through the menus.Use
Hold For: – Use this function to suspend controller operation and choose the suspension duration from Today,02-30 days, Permanent or None.Reset Prg’s:
Komentarze do niniejszej Instrukcji